Matching adjustment of ultrasonic generator and transducer

Matching adjustment of ultrasonic generator and transducer

the longer the ultrasonic transducer is stored, the more stable it is (the smaller the capacitance and impedance changes,Therefore, we recommend that the ultrasonic transducer be stored for at least 3 months after assembly before use.). Also, after the transducer is glued, it must be aged for 72 hours before it can be turned on and debugged (the curing time of Araldite glue is 24 hours).

When the water temperature is around 40 degrees Celsius, the ultrasonic effect is best. New water needs to be turned on for about 30 minutes to achieve the best effect (because there is more air in the new water, the air needs to be discharged before the cavitation effect can be better).

When matching with the ultrasonic generator, the current value is: when the number of transducers is less than or equal to 30, it is calculated according to 0.15A×30=4.5A. When the number of transducers is greater than or equal to 36, it is calculated according to 0.1A×50=5A.

If you have any questions during the debugging process, please feel free to communicate with us. The advantage of cooperating with me, in addition to the price advantage, is that we can share successful experience.

Get In Touch